  specification model plp-30-12 plp-30-24 plp-30-48 dc voltage rated current current range rated power output current adj. range line regulation load regulation setup time voltage range note.4 frequency range power factor (typ.) efficiency (typ.) ac current (typ.) input inrush current (max.) leakage current working temp. working humidity storage temp., humidity temp. coefficient vibration mtbf dimension others note packing over current note.5 short circuit over voltage 12v 24v 48v 18 ~ 24v 36 ~ 48v 2.5a 1.3a 0 ~ 1.3a 0.63a 0 ~ 0.63a 30w 31.2w 30.24w 2vp-p 2.4vp-p 0.975 ~ 1.3a 4.8vp-p 0.475 ~ 0.63a 10% 3.0% 5.0% 1200ms / 230vac 22 at full load 00ms / 115vac 90 ~ 264vac 127 ~ 370vdc 47 ~ 63hz pf>0.9 at 75 ~ 100% load , 115vac / 230vac 83% 85.5% 86.5% 15 ~ 18v 28 ~ 33v 57 ~ 63v 0.4a/115vac 0.2a/230vac 40a/230vac <0.75ma / 240vac protection type : constant current limiting, recovers automatical ly after fault condition is removed hiccup mode, recovers automatically after fault condition is remove d. -30 ~ +70 (refer to "derating curve") 20 ~ 95% rh non-condensing -40 ~ +80 , 10 ~ 95% rh 0.03%/ (0 ~ 50 ) 10 ~ 500hz, 2g 12min./1cycle, period for 72min. each along x, y, z axes 580.8khrs min. mil-hdbk-217f (25 ) 101.6*50.8*26.6mm (l*w*h) 1. all parameters not specially mentioned are measured at 230vac input, r ated load and 25 of ambient temperature. 2. ripple & noise are measured at 20mhz of bandwidth by using a 12" twisted pair- wire terminated with a 0.1uf & 47uf parallel capacitor. 3. tolerance : includes set up tolerance, line regulation and load regula tion. 4. derating may be needed under low input voltage. please check the static ch aracteristics for more details. 5. constant current operation region is within 75% ~100% rated output vol tage. this is the suitable operation region for led related application s, but please reconfirm special electrical requirements for some specific syste m design. 6. the power supply is considered as a component that will be operated in comb ination with final equipment. since emc performance will be affected by t he complete installation, the final equipment manufacturers must re- qualify emc directive on the complete installation again. 7. heat sink hs1,hs2 can not be shorted. 8. direct connecting to leds is suggested, but is not suitable for using addi tional drivers. 0.12kg; 108pcs/13kg/0.89cuft features : ripple & noise (max.) note.2 voltage tolerance note.3 environment safety & emc protection safety standards withstand voltage isolation resistance 1.875 ~ 2.5a 100 ~ 110% protection type : shut down o/p voltage, re-power on to recover 30w single output led power supply p l p - 3 0 s e r i e s constant current operation voltage note.5 9 ~ 12v 0 ~ 2.5a universal ac input / full rangeprotections: short circuit / over current / over voltage built-in active pfc function cooling by free air convection output current level adjustable 100% full load burn-in test high suitable for built-in applications of led lighting 2 years warranty class 2 power unit reliability i/p-o/p:3.75kvac i/p-fg:1.88kvac o/p-fg:0.5kvac i/p-o/p, i/p-fg, o/p-fg:100m ohms / 500vdc / 25 / 70% rh compliance to en55015, en61000-3-2 class c( 75% load); en61000-3- 3 compliance to en61000-4-2,3,4,5,6,8,11, en55024,en61547, li ght industry level, criteria a ul8750, tuv en61347-1, en61347-2-13, csa c22.2 no. 250.0-08(exc ept for 48v) approved ; design refer to ul60950-1 file name:plp-30-spec 2012-03-01 emc immunity emc emission ( for 48v only) ( except for 48v )
mechanical specification file name:plp-30-spec 2012-03-01 unit:mm derating curve static characteristics ambient temperature ( ) load (%) -30 -25 -5 0 20 40 50 60 70 20 40 60 80 100 input voltage (v) 60hz 90 100 125 135 145 155 165 175 180 200 230 264 100 90 80 70 60 50 40 load (%) (horizontal) fosc : 90khz(115vac) 120khz(230vac) block diagram detection pwm & pfc circuit o.l.p. emi filter rectifiers power switching filter & rectifiers +v -v i/p fg control o.v.p. & o.c.p. 50 ac input connector (cn1) : jst b3p-vh or equivalent dc output connector ( cn2) : jst b2p-vh or equivalent pin no. pin no. 1 1 3 2 2 assignment assignment ac/l +v ac/n -v no pin mating housing mating housing jst vhr jst vhr or equivalent or equivalent terminal terminal jst svh-21t-p1.1 jst svh-21t-p1.1 or equivalent or equivalent t1a /250v ac fuse cn1 12 3 cn2 hs2 hs1 svr1 12 3.175 95.25 101.6 fs1 26.6 3max. 3.175 . . 44.45 50.8 4- 3.2 hs1,hs2 can not be shorted : grounding required 30w single output led power supply p l p - 3 0 s e r i e s
46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 230v 115v 0 .7 8 0 .8 0 0 .8 2 0 .8 4 0 .8 6 0 .8 8 0 .9 0 0 .9 2 0 .9 4 0 .9 6 0 .9 8 1 .0 0 5 0 % 6 0 % 7 0 % 8 0 % 9 0 % 1 0 0 % 2 3 0 v 1 1 5 v plp-30 series possess superior working efficiency that up to 86.5% can be r eached in field applications. efficiency (%) load power factor characteristic efficiency vs load (48v model) constant current mode pf load driving methods of led module (30w) this led power supply is suggested to work in constant current mode area (cc) t o drive the leds. typical led power supply i-v curve vo(%) 100 75 50 100 (max.) io (%) constant current area hiccup protection file name:plp-30-spec 2012-03-01 30w single output led power supply p l p - 3 0 s e r i e s


▲Up To Search▲   

 
Price & Availability of PLP-3012

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X